TOPCON- Features
- ■ High dynamic range measuring(0.0005 – 500,000,000cd/m²)
- ■ Reduction of measuement speed. It can measure more speedy using High speed mode.
- ■ Significant improvement in usability by adopting a color touch panel.
- ■ Pursuit of the best function and compatibility for measurement system installation.
- ■ High accuracy measurement of flashing light (Synchronous measurement function / Integral time delay function).
- ■ Standard accessory software can control SR-5A and can process measured data with simple operation.
Description
SR-5A is a new generation spectroradiometer that can measure from ultra-low luminance to ultra-high luminance with high sensitivity and high speed.Measurement range at measurement angle 1° is ultra-low luminance from 0.0005 cd / m² to expands the range of high luminance to 500,000,000 cd / m².
SR-5A can measure ultra-high brightness LED without using an external ND filter.
SR-5A realize reduction of measurement time with renewal the optical system and improvement of internal system algorithm.
Significant improvement in usability by adopting big-size color touch panel.
Principal use
■ Luminance, Chromaticity, Color rendering index and Color temperature for LED Back light, LED lighting.
■ Luminance and Chromaticity of µLED/Mini LED、OLED、LCD, Tablet, Smart phone display.
■ Luminance and Chromaticity of head light and interior panel of automobile.
■ Used as optical characteristic evaluation sensor for system equipment.
■ Production line(high precision gamma measurement with spectral measuring),R&D(various evaluation such as IVL-measuring).
■ Used as optical characteristic evaluation sensor for system equipment.).
Specifications
Photo detector | Electronically cooled linear CCD |
---|---|
Dispersion element | Diffraction grating |
Optical system | Object lens : f= 82mm F2.5, Eyepiece lens : 5° view field |
Measuring angle | 2°/1°/0.2°/0.1° Selectable (Electric motor moved) |
Measuring distance | 250mm – ∞ (Distance from metallic tip of objective lens) |
Spectral band width | 5nm (Half bandwidth) |
Spectral accuracy | ±0.3nm *Hg emission lamp |
Wavelength range | 380 – 780nm |
Wavelength resolution | 1nm |
Measurement mode | Auto/Manual(Integral time/Frequency) External vertical sync signal input |
Measuring object | Spectral radiance : W・sr-1・m-2・nm-1 |
Measuring function | Radiance Le : W・sr-1・m-2, Luminance Lv : cd・m-2, CIE1931 chromaticity coordinates xy, CIE1976 chromaticity coordinates u’ v’, Tristimulus value XYZ, Correlated color temperature and Deviation, Dominant wavelength : nm , Peak wavelength : nm CIE standard observer 2°/ 10° |
Measuring luminance range(*1)(*2) | 2°:0.0005 – 1,500,000 cd/m2
1°:0.0005 – 4,500,000 cd/m2 0.2°:0.0125 – 100,000,000 cd/m2 0.1°: 0.05 – 500,000,000 cd/m2 |
Accuracy : luminance(*1) | ±2% or less |
Accuracy : chromaticity:(x,y) (*1) | x : ±0.0015、y : ±0.001 (1° : 0.0015 cd/m2 – 、0.2° : 0.0375 cd/m2 – 、0.1° : 0.15 cdm2 – ) |
Repeat accuracy : luminance(*3) | 1.5% : 0.0005 – 0.005 cd/m2 0.4% : 0.005 – 0.1 cd/m2 0.3% : 0.1 cd/m2 – |
Repeat accuracy : chromaticity(*4) | 0.005 : 0.0005 – 0.005 cd/m2 0.0015 : 0.005 – 0.1 cd/m2 0.0005 : 0.1 cd/m2 – |
Polarization characteristics | Luminance 1% or less Spectral radiance 2% or less (400 – 780nm) |
Interface | RS-232C、 USB 3.0 |
Power supply | Dedicated AC adapter AC100V-240V, 50/60Hz, DC12V |
Power Consumption | Approx. 30W |
Operating conditions | Temperature: 5 – 30℃, Humidity: 80%RH or less (No condensation) |
External dimensions (W×D×H) | 422×130×244mm |
Weight | Approx : 5.5kg |
*1 For standard illuminant A.
*2 Measurable range in Normal and High speed mode.
*3 2σ from 10 times continuous measurement at measuring angle 2° in normal speed mode.
*4 (Max – Min) value from 10 times continuous measurement at measuring angle 2°in normal mode.
*2 Measurable range in Normal and High speed mode.
*3 2σ from 10 times continuous measurement at measuring angle 2° in normal speed mode.
*4 (Max – Min) value from 10 times continuous measurement at measuring angle 2°in normal mode.